www.glp.de Wild Bar 16
18 Wild Bar 16 User Manual
Main menu
The following menus and commands are available in the Wild Bar 16 control panel.
Menus
Notes
DMX Address
001-512
Set fixture’s DMX start
address. Highest possible
address depends on
control mode.
Control Mode
M1 Basic
Set fixture’s DMX control
mode.
M2 Normal
Protocol Setup
Data In
DMX
Control via DMX protocol
Art-Net
Control via Art-Net
sACN
Control via sACN
iQ.Mesh
Control via iQ.Mesh
CRMX
Control via CRMX
Data Out
Standard
No incoming data is
converted
DMX (XLR)
Incoming data will be
output from the DMX XLRs
Ethernet
Config
Addressing Mode
Auto 2.x.x.x
Auto Addressing in the
range 2.x.x.x
Auto 10.x.x.x
Auto Addressing in the
range 10.x.x.x
DHCP
Get IP address by DHCP
Custom IP
Use Custom IP Address
Custom IP Address
000.000.000.000
Custom IP Subnet
000.000.000.000
ArtNet Port
0..32768
sACN Universe
1..63999
Linking
Options
iQ.Mesh
Link
Unlink
Pattern
Main link
Normal
Pattern Output depends
on Dimmer and Shutter of
the main fixture.
Independent
Pattern Output not
affected by main fixture
Dimmer and Shutter
Separate
patch Pixels
Engine
ON/OFF
Disabled
Only in Mode2 - if disabled
the pixel control patch
follows main controls
Enabled
Patch the pixels to another
universe/source, pixels are
always RGB
Main link
Normal
Pixel RGB depend on
Dimmer and Shutter of
main fixture
Independent
Pixel RGB not affected by
main fixture Dimmer and
Shutter
Bekijk gratis de handleiding van GLP WildBar 16, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.