GLP Matrix Eye 2 handleiding
Handleiding
Je bekijkt pagina 13 van 24

German Light Products Matrix Eye
Rev. 20250711-0 13
● To save a custom setting preset from 1 to 3, use the option Service → Advanced →
Save Settings.
● Load User Settings 1 to 3 loads one of three specic custom xture settings which
you have previously stored. You must conrm the function for 3 seconds before the
new settings are loaded (option Fixture Settings
→
Load User Settings
→
User
Settings 1-3).
● To return settings to default, use the option Fixture Settings→Load User
Settings→Setting Defaults.
Note: The Load User Settings and Setting Defaults commands will only affect settings
in the Fixture Settings group and will not affect DMX Address, Control Mode, Protocol
Type, IP Settings, etc. This helps avoid loss of communication with the controller.
Information
The Information submenu provides readouts of all relevant information such as the
error list if any errors have been detected, the xture’s serial number, rmware version,
device info, device hours counter, power cycles counter, DMX input monitor, signal
quality etc.
Manual Control
This menu gives different options for setting up the xture manually.
● Reset All: Performs a full xture reset to initialize all features and effects.
● Manual DMX: gives control of the xture from the menu. External DMX control has
priority so disconnect controllers to use this function.
You can load values from the No Signal stored scene, or save values you’ve set back
to the stored scene.
Service
The Service menu allows you to run tests on the xture and to save current settings to a
user preset.
Load Factory Defaults
Reloads all factory defaults over the entire xture and brings the xture into standard
show condition.
You must conrm the function for 3 seconds before the default settings are loaded.
Important! The factory default settings that are reloaded with this command include
all data and network conguration parameters such as DMX start address, IP
conguration etc. You may therefore lose communication with your controller.
The Load Factory Defaults command does not affect device counters and calibration.
Factory Menu
Important! Do not enter the Factory Menu if you are not a trained service
professional with service documentation or clear instructions from GLP Service.