www.glp.de DMX MODE 4
40 JDC Line 500 User Manual
11
RGB intensity
effects (Strobe
mode)
Off (normal sync flashes)
0
14
0
5.5
0
Snap
Single flash if change on flash rate
channel
15
29
5.9
11.4
Pulse
30
44
11.8
17.3
Pulse opening
45
59
17.6
23.1
Pulse closing
60
74
23.5
29.0
Pulse random
75
89
29.4
34.9
Pulse opening random
90
104
35.3
40.8
Pulse closing random
105
119
41.2
46.7
Double flash
120
134
47.1
52.5
Double flash random
135
149
52.9
58.4
Triple flash
150
164
58.8
64.3
Triple flash random
165
179
64.7
70.2
Spikes
180
194
70.6
76.1
Lightning
195
209
76.5
82.0
Random pixel flash
210
224
82.4
87.8
Random fixture flash
225
239
88.2
93.7
Flash offset between fixtures (adjust
offset on Global flash rate channel)
240
255
94.1
100
12
CTC
Open
0
10
0
3.9
0
Snap
10 000 K
11
11
4.3
4.3
Fade
12
254
4.7
99.2
2 500 K
255
255
100
100
13
Red
Intensity 0 → 100%
0
255
0
100
0
Fade
14
Green
Intensity 0 → 100%
0
255
0
100
0
Fade
15
Blue
Intensity 0 → 100%
0
255
0
100
0
Fade
16
RGB FX pattern
select
Off (all white patterns inactive)
0
11
0
4.3
0
Snap
Pattern 01
12
15
4.7
5.9
Patterns 02 … 49
...
Pattern 50
208
211
81.6
82.8
No function
212
247
83.1
100
17
RGB pattern step
select / speed
Pattern step 01
0
2
0
0.8
0
Snap
Pattern steps 02 … 39
Snap
Pattern step 40
117
119
45.9
46.7
Snap
No function
120
127
47.1
49.8
Snap
CW fast → slow
(run pattern step 1 … n)
128
190
50.2
74.5
Fade
Stop
191
192
74.9
75.3
Snap
CCW slow → fast
(run pattern step n … 1)
193
255
75.7
100
Fade
18
RGB pattern step
crossfading
No crossfading, snap from one step
to next
0
5
0
3.9
0
Snap
Snap → longest crossfade (fade in
and fade out times are identical)
6
127
4.3
49.0
Fade
No crossfading, snap from one step
to next
128
133
49.4
51.0
Snap
Snap → longest crossfade with tail
(fade-in time is shorter than fade
out time, creates a shadow effect)
134
255
51.4
100
Fade
19
RGB pattern
transition
No transition time, snap from one
pattern to next
0
10
0
3.9
0
Snap
Snap → 15 sec. transition time
11
68
4.3
26.7
Fade
No transition time, snap from one
pattern to next
69
73
27.1
28.6
Snap
FOB (Fade Over Blackout) transition,
Snap → 15 sec. transition time
74
130
29.0
51.0
Fade
No transition time, snap from one
pattern to next
131
135
51.4
52.9
Snap
FOF (Fade Over Full) transition,
Snap → 15 sec. transition time
136
193
53.3
75.7
Fade