GLP impression X5 Bar 1000 handleiding
Handleiding
Je bekijkt pagina 20 van 84

www.glp.de X5 Bar 1000
20 impression X5 Bar 1000 User Manual
● High mode sets the fixture to give maximum light output and suits operation in high
ambient temperatures. Fans are set to constant operation at high speed. Light
output intensity is limited smoothly if it becomes necessary in order to keep fixture
temperature at optimum level.
You can also use High mode to cool down a fixture quickly after a period of
operation or to help remove dust from cooling fans.
● Medium mode sets fans to constant operation at medium speed. Light output
intensity is reduced to a level where it will normally remain constant at ambient
temperatures of up to 45° C (113° F). Intensity is smoothly limited further if it
becomes necessary in order to keep fixture temperature at optimum level.
● Low mode sets fans to constant operation at low speed and is optimized for
minimum noise. Light output intensity is reduced to a level where it will normally
remain constant at ambient temperatures of up to 30° C (86° F). Intensity is
smoothly limited further if it becomes necessary in order to keep fixture temperature
at optimum level.
● Minimum mode operates as follows:
- If the fixture is at blackout, all unnecessary fans are shut down completely and
only fans that are absolutely necessary remain active. These fans operate at low
speed.
- As soon as the fixture emits light, other necessary fans may start but will stay at
minimum speed. Light output is limited.
Note: In all fan modes, if fixture temperature reaches a dangerous level, the LEDs are
shut down for a period until the fans have brought the temperature down to a safe
level.
Sub module mode / Sub fixture mode
The impression X5 Bar 1000 offers two options for controlling the Main module and Sub
modules:
● Normal – In this mode, all Sub module channels are subordinate to the Main
module channel group. This means that the intensity and shutter of the Main
module act as master intensity and master shutter for the whole fixture.
● Independent – In this mode, the Sub module channel group can be controlled
independently of the Main module channel group and acts as an independent
fixture.
Note that no matter which Sub module mode setting you select:
• The Mix Priority channel is still active and will affect how the two dependent or
independent fixtures are mixed.
• Some of the general color management channels of the Main module such as
CTC, CQC, M/G-Shift and Tungsten simulation will still affect the Sub module.