Main menu
The following menus and commands are available in the impression S500 Profile HO/HC
control panel. Options may also be set by RDM. Some options can be changed while
operating using the Control/Settings channel.
Menus
Notes
DMX Address
001-512
Set fixture’s DMX start
address. Highest possible
address depends on control
mode.
Protocol Setup
Data In
DMX
Control via DMX protocol
ArtNet
Control via Art-Net
sACN
Control via sACN
iQ.Mesh
Control via iQ.Mesh
CRMX (FPO) – only if CRMX module is installed
Control via sACN
Ethernet
Config
Addressing Mode
Auto 2.x.x.x
Auto 10.x.x.x
DHCP
Custom IP
Custom IP Address
0.0.0.0
Custom IP Subnet
0.0.0.0
ArtNet Port
0..32768
sACN Universe
1..63999
Node
Disabled
Received data (ArtNet,
sACN, CRMX) to be sent out
of DMX XLR port
Enabled
Linking
Options
iQ.Mesh Unlink
Unlink from existing
iQ.Mesh network
CRMX Unlink
Unlink from existing CRMX
network
Fixture Settings
Dimmer
Curve
Linear
Linear dimming curve
Soft
Soft (square law) dimming
curve
S-Curve
Finer dimming control at
low and high intensity
Fan Mode
Regulated
Fan speed temperature-
regulated
High
Fan speed constant high
Medium
Fan speed constant
medium
Low
Fan speed constant low
Minimum
All fans off or at minimum
speed
Performance
Fast
Set Mechanical effects
speed to control fixture
noise level.
Normal
Smooth