GLP impression S350 Wash handleiding
Handleiding
Je bekijkt pagina 34 van 44

www.glp.de
34 GLP impression S350 Wash User Manual Rev. C
25
(contd.)
Special/Control
(contd.)
Focus tracking off*
Focus tracking near*
Focus tracking medium*
Focus tracking far*
No function
Framing Control = PI Mode,
(position/Index)*
Framing Control = LR Mode,
(left/right)*
No function
PWM 2200 Hz **
PWM 3000 Hz **
PWM 4800 Hz **
PWM 9600 Hz **
No function
PWM 25 kHz **
Load setting defaults**
No function
Reset pan/tilt *
Reset head*
Reset all*
141 – 143
144 – 146
147 – 149
150 – 152
153 – 158
159 – 161
162 – 164
165 – 191
192 – 194
195 – 197
198 – 200
201 – 203
204 – 206
207 – 209
240 – 242
243 – 245
246 – 248
249 – 251
252 – 255
0 55.3 – 56.1%
56.5 – 57.3%
57.6 – 58.4%
58.8 – 59.6%
60.0 – 62.0%
62.4 – 63.1%
63.5 – 64.3%
64.7 – 74.9%
75.3 – 76.1%
76.5 – 77.3%
77.6 – 78.4%
78.8 – 79.6%
80.0 – 80.8%
81.2 – 82.0%
94.1 – 94.9%
95.3 – 96.1%
96.5 – 97.3%
97.6 – 98.4%
98.8 – 100%
Snap
26
FX1 selection No FX
LED cluster FX 01 Chaser
LED cluster FX 01 Crossfade
LED cluster FX 02 Chaser
LED cluster FX 02 Crossfade
LED cluster FX 03 Chaser
LED cluster FX 03 Crossfade
LED cluster FX 04 Chaser
random
LED cluster FX 04 Crossfade
random
No function
0 – 10
11 – 14
15 – 18
19 – 22
23 – 26
27 – 30
31 – 34
35 – 38
39 – 42
43-255
0 0 – 3.9%
4.3 – 5.5%
5.9 – 7.1%
7.5 – 8.6%
9 – 10.2%
10.6 – 11.8%
12.2 – 13.3%
13.7 – 14.9%
15.3 – 16.5%
16.9 – 100%
Snap
27
FX1 adjustment FX1 speed slow – fast 0 – 255 0 0 – 100% Fade
* Move from zero and hold value for 3 seconds to apply
** Move from zero and hold value for 5 seconds to apply
Notes:
Percentage values are calculated by dividing DMX values by 2.56 and rounding to the
nearest 0.1%.
To apply a command on Channel 25 (Special/Control), start at a value of zero, then
move to the required value and hold it for the required time (e.g. 3 seconds). If you
move to the required value from any other value than zero, the command will not be
applied.
To adjust the PWM frequency using the Special/Control channel, start at a value of
zero, move to the required value and hold it for at least 5 seconds.
Default settings are written in bold type.
Bekijk gratis de handleiding van GLP impression S350 Wash, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | GLP |
| Model | impression S350 Wash |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 4899 MB |







