GLP impression S350 Wash handleiding
Handleiding
Je bekijkt pagina 16 van 44

www.glp.de
16 GLP impression S350 Wash User Manual Rev. C
temperatures of up to 45° C (113° F). Intensity is smoothly limited further if it becomes
necessary in order to keep fixture temperature at optimum level.
• Fan constant low mode sets fans to constant operation at low speed and is optimized
for minimum noise. Light output intensity is reduced to a level where it will normally
remain constant at ambient temperatures of up to 30° C (86° F). Intensity is smoothly
limited further if it becomes necessary in order to keep fixture temperature at
optimum level.
In all fan modes, if fixture temperature reaches a dangerous level, LEDs will be shut
down for a period until the fans have brought the temperature down to a safe level.
You can set the cooling fan mode using the control panel or the Special/Control DMX
channel.
Performance settings
You can select between three different settings for the movement speed of all the
fixture’s mechanical effects (pan/tilt, color wheel, zoom, focus, etc.):
• In Normal mode, mechanical effects movement is set to give an optimum balance
between speed, quietness and smoothness. Normal is the default setting.
• In Fast mode, movement is set to maximum speed. This setting gives super-fast effects
but can result in higher noise levels.
• In Smooth mode, movement is set to optimize smoothness and give lowest-noise
performance. This setting gives extremely low noise and smooth performance but
effect movement will be slower than in Normal mode.
You can select Movement Performance using either the control panel or the
Special/Control DMX channel.
Effect wheel shortcuts
By default, the color wheel takes the shortest, fastest route from one slot to the next,
even if this means that it may pass through the open position. To avoid the wheel
passing through the open position when it changes from one slot to the next you can
set Effect shortcuts on the Special/Control DMX channel or in the control panel to OFF.
Behavior when the fixture is not receiving a DMX signal
You can set the fixture to react in four different ways if no DMX signal is present (if the
fixture is being controlled by DMX but the DMX signal stops, or if you apply power to
the fixture when no DMX signal is present):
• Hold sets the fixture to continue obeying the last DMX values it received. This is the
default setting.
• Blackout sets the fixture to black out whenever it is not receiving a DMX signal.
• Stand-Alone sets the fixture to play its stored stand-alone scene (see DMX Shot below)
when the fixture is not receiving a DMX signal. If no stand-alone scene is stored in
memory, the fixture will black out.
• DMX Shot takes a snapshot of the DMX values that are currently being received and
stores them in the fixture’s memory as its stand-alone scene. The fixture will display this