GLP FUSION X-PAR 8Z handleiding

51 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 15 van 51
German Light Products Settings
Rev. 20240416-01 15
Note that external DMX Values will always have higher priority than manually entered
values. We recommend that you disconnect the fixture from the data source when
using Manual DMX.
Manual DMX values are saved to the internal Scene (Stand Alone) memory as soon you
exit the Manual DMX menu. This scene can be replayed automatically using the No-
Signal Æ Scene (Stand Alone) function.
Manual Control: Manually sets a DMX value for each function.
Capture DMX values: Captures the external DMX signal values currently being
received and uses them as the manual control values.
Information
The Information submenu provides readouts of all relevant information such as the
error list if any errors have been detected, the fixture’s serial number, firmware version,
device info, device hours counter, power cycles counter, DMX input monitor, signal
quality etc.
Service
The Service menu contains the following items:
Test All: Runs a test sequence of all LEDs for a quick test of the fixture. Press BACK to
stop the test sequence.
Test LED only: Runs a test sequence of the LED pixel only. Press BACK to stop the
test sequence.
Test Zoom only: Runs a test sequence of Zoom functionality only. Press BACK to
stop the test sequence.
Default Settings: Sets options to default except: Captured Scene, DMX Address,
ControlMode, Preset Values, Offset Values.
Units: Allows Temperature units to be set to Centigrade or Farenheit.
Job Offsets: Lets you set +/- offsets to the zoom function, and the RGBL emitter
brightness for matching between fixtures.
Reset Counter: Allows you to reset various maintenance counters within the fixture:
Device Hours, Power Cycles, Lamp Hours, Max. Temperature, Temperature Unit
Load Factory Backup: (Hold Enter for 3 seconds to confirm) Resets all fixture
settings to default except User Hour Counter, Temperature Unit.