German Light Products DMX control modes overview
Rev. 20240416-1 25
6. DMX control modes overview
The Fusion X-PAR 18Z offers the following DMX control modes.
DMX Mode 1: Basic gives raw color
control using 8-bit RGB levels, with
overall dimmer and shutter controls.
The Lime channel has no effect unless
the fixture Color Mode is set to RGBL.
A Control / Settings channel lets you
configure the fixture remotely via
DMX.
Mode 1
Basic
1 Dimmer
2 Shutter
3 Zoom
4 Control
5 Red
6 Green
7 Blue
8 Lime
DMX Mode 2: Standard provides a
selection of fixed colors with overall
dimmer and shutter controls. If
Channel 9 is set below DMX 10 (3.9%)
then the color can be controlled by
the RGB(L) channels - the Lime
channel has no effect unless the
fixture Color Mode is set to RGBL. If
Channel 9 is DMX 10 or above,
Channels 5-8 have no effect.
The CTC and M/G shift channels
modify the color selected by the other
channels.
A Control / Settings channel lets you
configure the fixture remotely via
DMX.
Mode 2
Standard
1 Dimmer
2 Shutter
3 Zoom
4 Control
5 Red
6 Green
7 Blue
8 Lime
9 Color Wheel
10 CTC
11 M/G shift

Bekijk gratis de handleiding van GLP Fusion X-Par 18Z, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.