GLP Fusion X-Par 12Z handleiding
Handleiding
Je bekijkt pagina 25 van 55

German Light Products® Features
Fusion XPAR 12Z User Manual Rev. A 25
Figure 8. Dimming curves
● Linear sets dimming so that it appears to increase and decrease evenly throughout the
dimming range.
● Theatrical is an S-shaped curve that gives finer control at low and at high light levels.
● Square Law gives finer control at low light levels and coarser control at high light levels.
● Inverse Square Law gives coarser control at low light levels and finer control at high light
levels.
The default setting is Linear.
The fixture can be set to snap to dimmer changes or to have a soft-fade change similar to
a tungsten fixture. This is set using the Fixture Settings Æ Dimmer Speed option. The default
setting is Fast.
Shutter
The fixture has a simulated digital shutter with strobe and ramp up/ramp down effects
Zoom
The beam angle can be set between 6 and 44 degrees using the motorized micro-fresnel
lens. The Zoom operation can be inverted using the Fixture Settings Æ Zoom Invert menu
option.
Control Channel
All settable options from the onboard control panel can also be set remotely by DMX using
the Control channel. See DMX tables in the next section for details.
Behavior when the fixture is not receiving a DMX signal
You can set the fixture to react in three different ways if no DMX signal is present (if the
fixture is being controlled by DMX but the DMX signal stops, or if you apply power to the
fixture when no DMX signal is present):
● Hold sets the fixture to continue obeying the last DMX values it received. If the fixture is
powered up with no DMX signal, the fixture will remain in black out. This is the default
setting.
● Blackout sets the fixture to black out.
● Run Captured Scene sets the fixture to output the DMX state stored using the Fixture
Settings Æ Capture Scene option on the user menu.
This can be set using the Fixture Settings Æ No Signal menu option.
Bekijk gratis de handleiding van GLP Fusion X-Par 12Z, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | GLP |
| Model | Fusion X-Par 12Z |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 5678 MB |







