German Light Products® DoP Converter DINrail / UM
GLP DoP Converter User Manual Rev. 20220320-01 17
7. Connecting to DMX / RDM
If you would like advice with planning and installing a DMX / RDM link, your GLP
supplier will be happy to help.
Provide supports to carry the weight of all cable runs. Do not allow the weight of
cables to hang from screw terminals, as this may pull wires out of the terminals and
cause a failure of data transmission.
Transmitter mode
When in transmitter mode (TX), the DoP Converter inserts the DMX / RDM signal that is
present at its DMX IN terminals into a DoP signal and sends it over the mains power
cable that is connected to its PWR out terminals.
To connect a DMX controller to the DoP Converter:
1. Shut down power to the installation.
2. Prepare the DMX input cable by stripping approximately 6 mm (1/4 inch) of
insulation from the hot (positive) and cold (negative) conductors.
3. Fasten the conductors into the quick connector clip terminals marked DMX IN as
follows:
• Insert the shield conductor into the terminal marked GND
• Insert the hot DMX conductor into the terminal marked +
• Insert the cold DMX conductor into the terminal marked –
Check that the conductors are held securely and cannot be pulled out of the
terminals.
If needed, you can use the DoP Converter’s DMX OUT connections to relay the DMX
signal through multiple DoP Converters and to other DMX devices in a DMX daisy
chain.
Receiver mode
When in receiver mode (RX), the DoP Converter demodulates the DMX / RDM signal
from the mains power cable that is connected to its PWR IN terminals and relays it to
other DMX-controlled devices via DMX cable connected to its DMX OUT terminals.
To connect DMX-controlled devices to the DoP Converter:
1. Shut down power to the installation.
2. Prepare the DMX output / throughput cable by stripping approximately 6 mm (0.3
inches) of insulation from the hot (positive) and cold (negative) conductors.
3. Fasten the conductors into the quick connector clip terminals marked DMX OUT as
follows:
• Insert the shield conductor into the terminal marked GND
• Insert the hot DMX conductor into the terminal marked +
• Insert the cold DMX conductor into the terminal marked –