Rangehoods
Rangehoods and overhead exhaust fans must be installed according to manufacturers’
instructions but in no case shall clearance from hob burners be less than 600 mm for a
rangehood and 750 mm for overhead exhaust fan.
Ventilation
A cooker should not be installed in any room which has a volume less than 5.6 cu. m.
(200 cu. ft.). If the room is between 5.6 Cu. m. (200 cu. ft.) and 11.2 cu. m. (400 Cu. ft.)
in volume, provision must be made for permanent ventilation. Above 11.2 cu. m. (400 cu.
ft.) volume, no special provision needs to be made unless other gas burning appliances
are installed in the same room. Ventilation must always be provided if a cooker is
installed in a cellar or a basement. The manufacturer does not accept damage caused
directly or indirectly by failure to comply with the above.
750mm
600mm
Allow a 5mm gap
on each side