Model: GVHC & FOperation & Filter Maintenance
NEVER attempt to clean and reuse a Charcoal Filter. Doing so can result in hood damage
or malfunction.
The charcoal filter is a singleuse, consumable item which must be routinely replaced with a fresh new filter, see
Sections 4.02.2 & 4.02.3. Charcoal filters CANNOT be cleaned and reused.
Typical replacement frequency is 30 to 40 days, depending on foods being cooked & activity.
Use Giles replacement Item No. 30248. Record date on the new filter as reference.
4.03.3 Charcoal Filter Maintenance
1
IMPORTANT: Failure to use Giles OEM parts and OEM replacement filters may void the factory warranty.
4.03.2.2 E.A.C. Cell Cleaning Alternative Soak Method (continued)
NOTE:
The degreasing solution can be used multiple times ... to prevent contamination, place a lid or other suitable
cover on container when not using. Discard and replenish the degreasing solution when a greasy film remains
visible on the surface of the liquid.
When soaking, always ensure that the solution completely covers the cell ... add some water if needed.
3. After preparing the proper quantity of degreasing solution to completely cover cell in the
soak container, hold cell by the contact plate
, frame, or the handle and carefully place
it into the solution. Be sure it is fully submerged.
4. Allow cell to soak for approximately 20 minutes (no more than 30 mins), then lift it
slightly and agitate it up & down briefly in the solution to help dislodge grease residue.
5. Carefully remove cell from container and follow Steps 4 thru 6 as previously detailed in
Section 4.03.2.2.