Giles GVH-F handleiding

68 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 46 van 68
36
Model: GVHC & F Operation & Filter Maintenance
4. Carefully move cell to sink and rinse thoroughly, using hot water spray. Rinse ONLY, DO NOT
scrub with brushes.
5. On a drain board, stand cell upright on end with contact plate up ... allow it to drain and air dry
overnight. Cell must be completely dry before being replaced in hood. If desired, a small
electric fan can be used to blow across the cell to help expedite drying.
6. Before replacing cell in the hood, inspect for broken/missing ionizer wires and bent fins.
Broken or missing wires need to be replaced promptly. Bent fins may be straightened by
hand so that no fins are touching adjacent fins.
IMPORTANT! ONLY Simple Green® Crystal Foaming Cleaner/Degreaser is recommended for
cleaning cell in this manner. Other spray cleaner products may contain corrosive ingredients that can damage the
metal components, causing it to fail or not perform properly. Such damages are not covered by the factory
warranty.
4.03.2.2 E.A.C. Cell Cleaning Alternative Soak Method
4.03.2.1 E.A.C. Cell Cleaning Preferred Spray Method (continued)
The factoryrecommended product to use for cleaning the E.A.C. cell in this manner is Simple Green® ProHD. It is
a readily available, biodegradable, nontoxic degreasing cleaner that is safe for use on aluminum. It performs well
to clean the cell when diluted at a 1:12 ratio (e.g. 1/2 gal. cleaner to 6 gals ambient water).
DO NOT use DISHWASHING DETERGENTS or CORROSIVE CLEANERS as they can contain ingredients that may
damage metal cell components, causing failure or unsatisfactory performance. Such damages are not covered by
the factory warranty.
1. Cleaning with this method requires a suitable, leakproof container, such as a tall trash bin, recycle
bin, plastic tote, or the GILES soak tank*. Container must be large enough to hold the cell along
with enough degreasing solution for it to be submerged completely for soaking (either standing on
end, edge, or lying flat).
2. Fill container with fresh water to a level that will basically cover the cell. Measure
water as container is filled and note the quantity. Add Simple Green® ProHD in the
ratio of 1:12 to the water (e.g. 8 gals of water would require 2/3 gal (2 qts+211/2
ozs) of degreaser. Stir solution well to mix.
* NOTE: The GILES soak tank (purchased separately, Item# 91123) is specifically designed & sized
for soaking the EAC cell. Add 1/2 gal. of the cleaner & fill to the marked “FILL” line with clean
water.