Giles GVH-F handleiding

68 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 44 van 68
34
Model: GVHC & F Operation & Filter Maintenance
4.02.4.3 E.A.C. Filter Status & Alarm continued
3. Inspect cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are replaceable (when
ordering replacements, note that the GVH hoods use 20” wires). Bent fins may be gently straightened by hand,
such that no fins are touching adjacent fins. If cell is damp with moisture, allow it to air dry. Excessively
damaged cells (broken or badly bent frame, broken insulators, etc) must be replaced.
4. Inspect the E.A.C. contact pad inside hood. Clean grease accumulation away with a mild degreasing cleaner and
dry thoroughly.
5. Replace collector cell (Section 4.02.3) and restart hood (Section 4.01.1). If the condition persist or if none of
the LED lights turn ON, the EAC power supply may be faulty ... call for service.
4.03 Filter Maintenance
4.03.1 Baffle Filter Cleaning
4.03.2 E.A.C. Filter Cell Cleaning
Continued on Next Page
Cleaning frequency can depend on types of cooking appliance being used, but daily cleaning is, typically, preferred.
Rotate the thumbturns to the unlocked position and open the filter halves. Clean in sink with a mild,
biodegradable, degreasing cleaner (Giles recommends Simple Green®Crystal Foaming Cleaner). Rinse and dry
thoroughly. Close filter halves, secure the locking thumbturns and reinstall. Generally, the baffle filters may be
washed in a dishwasher.
Ensure that filter is completely dry before reinstalling. NEVER PLACE WET FILTER INTO HOOD!
The stainless steel baffle filter is fabricated from thin guage sheet metal that can potentially
present sharp edges. Exercise due care when handling and cleaning to avoid injury. It is
recommended to wear heavyduty rubber gloves.
The E.A.C. collector cell contains parts fabricated from thin gauge sheet metal that can
potentially present sharp edges, which may cause finger cuts if not handled properly. To
avoid injury, exercise due care when handling and/or cleaning the cell. It is recommended to
wear heavyduty rubber gloves as a precaution.
The E.A.C. collector cell is sustainable and renewable; it should last for years if cleaned and handled properly. To
maintain peak performance, It MUST BE CLEANED DAILY. Failure to do so can lead to interruptions in cooking
appliance operation, premature failure of the electronic cleaning system, or reduced useful life of consumable
charcoal filters. Follow the procedures detailed below for effective cleaning.
IMPORTANT:
The cell CANNOT
withstand washing in commercial dishwashing equipment.
Many commercial cleaners are not safe for aluminum ... using the recommended cleaners is advised.
Dishwashing detergents are generally not suitable ... they can cause oxidation, or create a film on aluminum
collection fins that will lead to malfunction and result in interruption of power to underhood cooking
appliances.