Model: GVHC & FOverview
3.01 Control Panel
Item Description Function
1
POWER Switch
(PushToStart)
The POWER switch has (3) positions. Pressing & momentarily
holding the top [START] portion of the switch starts hood and
engages interlock relay to power appliances underneath. When
released, switch remains [ON] (centered). Pressing [OFF] (bottom
of switch) powers off hood and appliance supply power.
2 HOOD POWERED Light
Green light is ON when the POWER switch is in the [ON] position.
The filter access door must be properly closed & secured before
hood will powerup.
3 APPLIANCE POWERED Light
Amber light is ON to signal that appliances underneath the hood are
receiving power and ready for use.
4
E.A.C. Filter Status
Indicators
LED light cluster indicates the status of the Electronic Air Cleaner
(E.A.C.) system.
[ON] Turns ON when hood is poweredup. Indicates that the
system is powered and functioning normally to clean the air. This
will be the only light ON when system is operating properly.
[WASH] Indicates excessive grease buildup on collector fins
(dirty), collector cell is missing or has poor contact, too many ionizer
wires missing, etc. Approximately 2 minutes after this light turns
ON, a beeping alarm will begin sounding and power to appliances is
shutdown.
IMPORTANT! Do not rely on this indicator as a signal for routine
cell cleaning; Giles recommends daily cleaning to maintain peak
performance and extend the useful life of charcoal filters.
[CHECK] Indicates that collector cell has stopped operating
properly; damaged & shorted to ground, fins shorted due to
excessive moisture, etc. No alarm sounds & appliances remain
powered, but air cleaning system is not functioning.
5
CHARCOAL OR BAFFLE FILTER
CLOGGED Light
Red light will turn ON if either the charcoal or baffle filter is dirty &
clogged, or there are other airflow obstructions is present.
6
CHARCOAL OR BAFFLE FILTER
MISSING Light
Red light will turn ON if either the charcoal or baffle filter is missing
or installed improperly.
7
EAC Cleaning Timer
[CHANGE SOON] Indicator
Turns ON when timer enters [WARNING MODE] to indicate that the
collector cell must be cleaned within the next 24 hours.
8
EAC Cleaning Timer
[CHANGE NOW]
Indicator
Turns ON when timer enters [TIMEOUT MODE] to indicate that the
maximum time between cleanings has expired. Cell must be
cleaned immediately. Power to appliances is shutdown until
cleaning is performed. Timer will reset after cleaning.
9
EAC Cleaning Timer
[SNOOZE]
Button
Pressing button, after [TIMEOUT] is active will return timer to
[WARNING MODE] and allows use of appliances for two (2)
additional hours. Two (2) [SNOOZE] periods can be used.
Afterward, power to appliances is shutdown & lockedout until
cleaning is completed.