Giles GVH-F handleiding

68 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 19 van 68
9
Model: GVHC & FInstallation
B
MIN.
C
MAX.
HEATING
AREA
A
MIN.
A
MIN.
HEATING
AREA
APPLIANCE RESTRICTIONS
APPLIANCE A B C D MAX. AMP.
MAX. SURFACE
AREA
MAX. SHORTENING
CAPACITY
MAX.
TEMP
MAX
ELEMENTS
FRYER(S) 1-1/2 8 N/A 19
100 TOTAL* (MAX 50AMP
THROUGH HOOD
INTERLOCK CONTACTOR)
576 SQ. IN.
0LBS/GAL



N/A
GRIDDLE 3-7/8 8-3/4 19 N/A 35 480 SQ. IN. N/A 450F N/A
RANGE 4 8-3/4 19 N/A 44 TOTAL ALL BURNERS N/A N/A N/A 4
OVEN 1 8-3/4 19 N/A
55 TOTAL* (MAX 50AMP
THROUGH HOOD
INTERLOCK CONTACTOR)
N/A N/A 500F N/A
CONVEYOR
OVEN
5-1/2 8 19 N/A
55 TOTAL* (MAX 50AMP
THROUGH HOOD
INTERLOCK CONTACTOR)
N/A N/A 500F N/A
TOASTER 1 8-3/4 19 N/A
55 TOTAL* (MAX 50AMP
THROUGH HOOD
INTERLOCK CONTACTOR)
N/A N/A 500F N/A
31 7/8 INSIDE
27 1/2 INSIDE
30 1/2
D
MAX.
HOOD APPROVED FOR ELECTRICALLY HEATED APPLIANCES ONLY.
* Appliance(s) exceeding 50A must be powered through a circuit separate from the hood and be interlocked
through the hood’s contactor coil.
2.04 Cooking Appliance Limitations & Clearances
2.04.1 GVHCCounterTop Hood