5.01.2 E.A.C. Filter Cell Cleaning - continued
Free Standing Ventless Hood
FSH-2 & FSH-2A-99
Cleaning &
Maintenance
Two (2) different cleaning methods are endorsed by GILES Food Service, as follows.
• Preferred: Spray Foam ‐ uses Simple Green® Crystal Foaming Spray Cleaner/Degreaser. A readily
available foaming aerosol that is an exceptionally effective cleaner, as well as being safe for use on alu
minum (NSF approved, foodgrade, nontoxic & biodegradable). Cleaning the E.A.C. cell is quick &
easy with this convenient readytouse cleaner. A complimentary sample has been supplied with
your new equipment. It can be ordered from Giles, item #41510 (12‐count case) or is also available
from various online sources & retail outlets. When used as directed, a case of cleaner should last ap
proximately 4 to 5 weeks, depending on equipment model.
• Alternative: Soaking ‐ uses a diluted solution of Simple Green® Pro‐HD & water. Although not as convenient as
the spray method, requiring more planning and time, the procedure has proven to be very satisfactory for clean
ing E.A.C. collector cells for many years. This product has the same characteristics of the spray product, but re
quires mixing with water before use ... dilution factor is 1:12, e.g. mix 1/2 gal. of cleaner with 6 gals. of water.
With proper care, cleaning, and handling, the E.A.C. collector cell is sustainable, designed to provide years of service.
While handling & cleaning the cell, take care not to bend the collector fins or break the fine
ionizer wires that are stretched across the cell face. Bent fins & broken/missing wires can
prevent the electronic collection system from performing properly. System faults & alarms will occur that can
potentially interrupt operation.
Damage from abusive handling and/or improper maintenance may not be covered by the factory warranty.
Ionizer Wire
(9) required
1. Remove collector cell from hood (see Section 4.02.4) and lay on a drain
board, or other suitable surface.
2. Hold can at the appropriate distance & spray Simple Green®
Crystal Foaming Degreaser onto the cell, completely covering
all surfaces ... collector fins, contact plate, brass fittings &
inside corners of the frame. Turn cell over & apply to the
other side in like manner, ensuring that both sides of all
collector fins are completely covered with the foam.
3. Allow foam to soak for 5 to 10 minutes. In cases of extreme
buildup, a second application may be required after rinsing.
A. Preferred Cleaning Method − Spray Cleaner
Fin