Gefen GEF-DVI-16416-PB handleiding

51 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 34 van 51
31
Commands
Simpli ed syntax was used for command implementation for faster operation with
the device: character – isn’t needed, the command name is reduced to 1 letter.
The commands are not case-sensitive.
Command Description
R Routing command
S Routes a single input to all outputs
M Returns the current routing status of matrix
F Toggle 5V ber optic extender feature
R Command
The R command allows speci c routing of inputs and outputs.
Syntax:
r param1 param2
Parameters:
param1 DVI Ouput [1 - 16]
param2 DVI Input [1 - 16]
S Command
The S command routes a single input to all 16 DVI outputs.
Syntax:
s param1
Parameters:
param1 Input [1 - 16]
Notes:
Setting param1 to a value of 0 will place the matrix in one-to-one mode. This
means that Input1 will be routed to Output1, Input2 will be routed to Output2, and
so on.