Gefen GEF-DVI-16416-PB handleiding
Handleiding
Je bekijkt pagina 26 van 51

23
#EDIDBATOLO Function
The #EDIDBATOLO function reads the downstream EDID and stores it to any
local input.
Syntax:
#EDIDBATOLO param1 param2 param3...param9
Parameters:
param1 EDID bank offset [1 - 5]
param2 All Inputs 0
param3 (optional) Input [1 - 16]
Notes:
By specifying zero as the second parameter, the EDID in the specifi ed bank is
copied to all sixteen inputs. When denoting specifi c inputs, param2 is not used.
If more than eight inputs need be specifi ed to receive the EDID in the specifi ed
bank, the #EDIDBATOLO function must be executed twice.
Example:
#EDIDBATOLO 5 2 3 4 5 6 7 8 9 10 11 12 not permitted!
Instead, run the function twice:
#EDIDBATOLO 5 2 3 4 5 6 7 8 9 10 max 9 inputs
#EDIDDSTOLO 5 11 12 remaining inputs
#PRDSEDID Function
The #PRDSEDID function reads the downstream EDID and sends it to the serial
port.
Syntax:
#PRDSEDID param1
Parameters:
param1 A downstream monitor [1 - 16]
RS-232 SERIAL CONTROL COMMANDS