Commands
IP Address (#SET_ / #GET_)
SET the IP Address.
Syntax
#SET_IP_ADDRESS PARAM1
Parameters
PARAM1 = XXX.XXX.XXX.XXX
XXX - 0 ~ 255
Examples
#SET_IP_ADDRESS 192.168.1.72
GET the current IP Address.
Syntax
#GET_IP_ADDRESS
IP Mode (#SET_ / #GET_)
SET the IP Mode to STATIC or DHCP.
Syntax
#SET_IP_ADDRESS PARAM1
Parameters
#SET_IP_MODE PARAM1
PARAM1 = 0 ~ 1
0 - STATIC
1 - DHCP
Examples
#SET_IP_MODE 0
GET the current IP mode.
Syntax
#GET_IP_MODE
MAC Address
Print the MAC address to the screen.
Syntax
#GET_MAC_ADDR
Main Reduction (#SET_ / #GET_)
SET main (source) volume reduction amount when mic is active when using the "auto" microphone
mixer mode.
Syntax
#SET_MAIN_REDUCTION PARAM1
Parameters
PARAM1 = 1 ~ 24
1 ~ 24 - DECIBELS OF MAIN (SOURCE) VOLUME REDUCTION
Examples
#SET_FEEDBACK 1
GET main (source) volume reduction amount when mic is active when using the "auto" microphone
mixer mode.
Syntax
#GET_MAIN_REDUCTION