Gefen EXT-4K600A-MF-51 handleiding

80 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 61 van 80
page | 51
Commands
EDID Lock (#SET_ / #GET_)
SET input EDID Lock (prevents accidental custom EDID overwrite and valid only when EDID mode is
set to custom mode).
Syntax
#SET_EDID_LOCK PARAM1
Parameters
PARAM1 = 1 ~ 4
1 - HDMI INPUT 1
2 - HDMI INPUT 2
3 - HDMI INPUT 3
4 - DISPLAYPORT INPUT
PARAM2 = 0 ~ 1
0 - DISABLED
1 - ENABLED
Examples
#SET_EDID_LOCK 1 0
GET input EDID Lock status.
Syntax
#GET_EDID_LOCK PARAM1
Parameters
PARAM1 = 1 ~ 4
1 - HDMI INPUT 1
2 - HDMI INPUT 2
3 - HDMI INPUT 3
4 - DISPLAYPORT INPUT
Examples
#GET_EDID_LOCK 1
EDID Mode (#SET_ / #GET_)
SET input EDID Mode.
Syntax
#SET_EDID_MODE PARAM1 PARAM2
Parameters
PARAM1 = 1 ~ 4
1 - HDMI INPUT 1
2 - HDMI INPUT 2
3 - HDMI INPUT 3
4 - DISPLAYPORT INPUT
PARAM2 = 1 ~ 6
1 - INTERNAL - 1080P 2 CH
2 - INTERNAL - 4K UHD 300 MHZ 2 CH
3 - INTERNAL - 4K UHD 600 MHZ 2 CH
4 - EXTERNAL (LOCAL HDMI)
5 - EXTERNAL (HDBASET)
6 - CUSTOM MODE - USER
Examples
#SET_EDID_MODE 1 3
GET input EDID mode.
Syntax
#GET_EDID_MODE PARAM1
Parameters
PARAM1 = 0 ~ 4
0 - ALL INPUTS (FEEDBACK LISTS ALL INPUTS IN ORDER 1 ~ 4)
1 - HDMI INPUT 1
2 - HDMI INPUT 2
3 - HDMI INPUT 3
4 - DISPLAYPORT INPUT
Examples
#GET_EDID_MODE 1; #GET_EDID_MODE 0