RS-232 and IP Conguration
Using Telnet
1. Launch the desired terminal application. For example, on the Windows operating
system, we can use Hyperterminal; on Mac OS X, we can use the Terminal
application.
2. In this example, we will use Terminal in Mac OS X. At the command prompt, type the
following:
telnet IP_address
where
IP_address
is the IP address of the 4x1 Multiview Seamless Switcher.
3. After correct settings have been used in the terminal program, information similar to the
following will be displayed:
********Welcome to the EXT-4K600A-MF-51-HBTLS********
Firmware Version: v3.66
***************************************************
>
4. Type
#help
for a list of commands or refer to the tables on the following pages.
Using RS-232
1. Launch the desired terminal application.
2. Selected the assigned COM port.
3. Congure the RS-232 port to the following settings.
Description Setting
Baud rate
19200 (default)
Data bits
8
Parity
None
Stop bits
1
Hardware ow control
None
4. Connect to the RS-232 port (DB-9 connector). Only TxD, RxD, and GND pins are used.
5. Type
#help
for a list of commands or refer to the tables on the following pages.
NOTE: Depending upon the network, all related IP and Telnet
settings will need to be assigned. Consult your network administrator
to obtain the proper settings.
It is highly recommended that you disable ECHO when controlling a
serial (RS-232) device from a remote receiver. This setting can be
changed with the command #SET_ECHO (pg. 50) using the RS-232
or IP Control interface.