Installation Instructions
EXHAUSTING THE DRYER (cont.)
STANDARD REAR EXHAUST
We recommend that you install your dryer before
installing your washer. This will permit direct
access for easier exhaust connection.
Slide the end of the exhaust duct on the back of the
dryer and secure with UL listed aluminum foil tape or
a hose clamp.
NOTE: We strongly recommend using rigid metal
exhaust duct. However, if flexible ducting is used it
must be UL-Listed metal, not plastic.
For straight line installation, connect the dryer
exhaust to the external exhaust hood using UL listed
aluminum foil tape or clamp.
RECOMMENDED CONFIGURATION
TO MINIMIZE EXHAUST BLOCKAGE
Using duct elbows will prevent duct kinking and
collapsing.
4" Metal duct cut
to proper length
External duct
opening
UL listed aluminum foil
tape or duct clamp
UL listed aluminum foil
tape or duct clamp
Transition
Ducting
BEFORE YOU BEGIN
Remove and discard existing plastic or metal foil
duct and replace with UL listed duct.
Remove any lint from the wall exhaust opening.
Internal
Duct
Opening
Wall
Check that exhaust
hood damper
opens and closes
freely.
EXHAUST SYSTEM CHECKLIST
HOOD OR WALL CAP
Terminate in a manner to prevent back drafts or entry of
birds or other wildlife.
Termination should present minimal resistance to
the exhaust airflow and should require little or no
maintenance to prevent clogging.
Wall caps must be installed at least 12” above ground
level or any other obstruction with the opening pointed
down.
SEPARATION OF TURNS
For best performance, separate all turns by at least
4 ft. of straight duct, including distance between
last turn and dampened exhaust hood (wall cap).
SEALING OF JOINTS
All joints should be tight to avoid leaks. The male end
of each section of duct must point away from the dryer.
Duct joints should be made air- and moisture-tight
by wrapping the overlapped joints with UL listed
aluminum foil tape.
Do not assemble ductwork with any fasteners that
extend into the duct. These fasteners can accumulate
lint, creating a potential fire hazard.
Horizontal runs should slope down towards the
outdoors 1/4” per foot.
Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once a year.
INSULATION
Ductwork that runs through an unheated area or is
near air conditioning should be insulated to reduce
condensation and lint build-up.