Troubleshooting Tips...Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
TROUBLESHOOTING TIPS
Problem Possible Cause What To Do
Air conditioner
does not start.
The unit is unplugged. Make sure the air conditioner plug is pushed
completely into the outlet.
The fuse is blown/circuit breaker is
tripped.
Check the house fuse/circuit breaker box and
replace the fuse or reset the breaker.
Power Failure. The unit will automatically restart in the setting
last used after the power is restored.
There is a protective time delay (approximately
3 minutes) to prevent tripping of the compressor
overload. For this reason, the unit may not start
normal cooling for 3 minutes after it is turned back
on.
The current interrupter device is
tripped.
Press RESET button located on the power cord
plug.
If the RESET button will not stay engaged,
discontinue use of the air conditioner and contact
a qualified service technician.
Air conditioner
freezing up
Ice blocks the air flow and stops
the air conditioner from cooling the
room.
Set the mode control to High Fan or High Cool
with the temperature setting as high as it can be
set.
Air conditioner
does not cool as it
should.
Indoor airflow is restricted. Make sure there are not curtains, blinds or
furniture blocking the front of the air conditioner.
The temp control may not be set
properly.
In the Cool mode, press the Decrease pad
The air filter is dirty. Clean the filter at least every 30 days. See
Operating Instructions section.
The room may have been hot. When the air conditioner is first turned on, you
need to allow time for the room to cool down.
Cold air is escaping. Check for open furnace registers and cold air
returns. Set the air conditioner’s vent to the
closed position.
Cooling coils have iced up. See “Air conditioner freezing up´DERYH
Air conditioner
does not warm as
it should
Indoor airflow is restricted. Make sure there are not curtains, blinds or
furniture blocking the front of the air conditioner.
The temp control may not be set
properly.
In the Heat mode, press the Increase pad
The air filter is dirty. Clean the filter at least every 30 days. See
Operating Instructions section.
The room may have been cold When the air conditioner is first turned on, you
need to allow time for the room to warm up..
Warm air is escaping. Check for open furnace registers and cold air
returns.
The remote control
is not working
The batteries are inserted
incorrectly.
Check the position of the batteries. They should
be inserted in the opposite (+) and (–) direction.
The batteries may be dead. Replace the batteries.