User Manual
Cleaning the Condenser Coil
• For efficient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
• Clean the condenser with a commercial condenser coil cleaner, available from any kitchen
equipment retailer. Ex. Nobel Chemical Tech Line.
Troubleshooting
Compressor is Not Running
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat set too high. Set thermostat to lower temperature.
Cabinet Temperature is too Warm
Thermostat is set too high. Set thermostat to lower temperature.
Airflow is blocked. Rearrange products to allow for proper airflow. Make
sure there is at least four inches of clearance from
the fan.
Low refrigerant levels. Contact a service technician to check refrigerant levels.
Door is slightly ajar. Make sure door is completely closed.
Unit's evaoprator has iced over. Conduct a manual defrost.
Interior Light is Not Working
Poor switch connection. Turn off light switch and turn it back on.
Bulb is not connected. Make sure the bulb is correctly inserted in the socket.
Bulb has burned out. Replace the bulb.
Condensation is Collecting on the Cabinet and/or Floor
Gasket is not sealing properly. Clean, repair, or replace the gasket as necessary.