13
English
Adjusting the grid height
To reduce the cup clearance and use smaller espresso cups.
1 Place the telescopic drain tube at its shortest position.
2 Lift the drip tray and position it via the dedicated guides as shown in the
drawing
Brew pressure adjustment
It is possible to adjust the brew pressure by rotating the external adjustment screw
(17) which is factory-set at 9 bars.
To adjust the brew pressure:
1 Disable the PRESET function if active.
2 Insert in the brew unit the lter holder with the blind lter.
3 Press the espresso toggle switch and read the bars on the manometer (34).
4 With a screwdriver rotate anticlockwise (-) to reduce the pressure or clockwise
(+) to increase it.
5 Stop the brewing by pressing the espresso toggle switch again when you
reach the desired bars on the brew gauge. .
6 Remove the lter holder and replace the blind lter with the 1 or 2 cups lter.
7 The machine is now ready for brewing.
Note: do not adjust the brew pressure by using the 1 cup or 2 cups lters. Use only
the blind lter.
Note: to avoid the risk of burns, do not remove the lter holder before point 5.
Note: the machine is equipped with a protection system so that if you activate the
coffee dispensing with the blind lter inserted for a time longer than 90 seconds,
the alarm E16 appears. This is normal, not a product defect.