2. MAINTENANCE
2-10
grease and then reapply the specified silicone grease (type:100946, code no.:
001-365-040).
Extended self test procedure for VR-7021F
1. Remove the capsule from the bracket.
2. Move the lever to “TEST” position twice within 3 seconds and return it to “READY”
position.
The GPS test starts and a short beep sounds every 3 seconds until GPS position
is acquired. The GPS test may take up to 2 minutes.
3. Two beeps sound for normal operation. Multiple beeps sound for error, as shown
in the table below.
4. The normal self test is started after the GPS test. Confirm that the strobe light
flashes once.
When the result of the self test is not “OK”, change the location and do the normal
self test. If not resolved, contact your dealer.
5. Check that the grease at the bottom of the capsule is sufficient and free of foreign
material. Reapply if necessary. Return the capsule to the bracket.
2.2.5 Annual Performance Test for the Float-free DRU
The Float-free DRU must undergo an annual performance test because it is a part of
the VDR system. Annual performance test is defined in the regulation of SOLAS. For
Japanese-flagged vessel, the radio inspection is required by the Ministry of Internal
Affairs and Communications.
For foreign-flagged vessel
All units in the VDR system must undergo an annual performance test. This test is
conducted by a test engineer authorized by the manufacturer and certified by a rele-
vant ship classification society. The EPIRB performance test for the Float-free DRU is
conducted by a engineer or service provider responsible for Jotron’s Tron40S MkII/
Tron40GPS/Tron40VDR AIS.
For Japanese-flagged vessel
For Japanese-flagged vessel, the radio inspection is required by the Ministry of Inter-
nal Affairs and Communications. This inspection is conducted by a engineer autho-
rized by the Ministry of Internal Affairs and Communications, such as GMDSS service
station of the Japan Ship-Machinery Quality Control Association. For the VDR annual
performance test and Float-free DRU performance test is conducted by a engineer au-
thorized by the Ship’s Electric Installation Contractors’ Association of Japan.
2.2.6 Shore-Based Maintenance (SBM)
The capsule of the Float-free DRU has the same functionality of an satellite EPIRB
(Emergency Position-Indicating Radio Beacon). So, it is required to conduct the SBM
in accordance with IMO guidelines at intervals specified by flag administration, within
five years from installation or previous SBM. Also, the battery in the capsule must be
Number of beeps Result
2
5
10
OK.
GPS positioning error.
Number of GPS tests performed exceeds the limit.