5. MENU OPERATION
5-5
5.6.1 How to adjust the EPFS alarm message timing
The system outputs an EPFS alert when the position of Own Ship cannot be found. In
some cases, the system is still obtaining information from connected sensors. In cases
where system takes a short while to receive the position information, you can adjust
the time it takes for the alert to appear.
[FIRST ALARM] sets the time to wait from when the power is turned on before releas-
ing an EPFS alert.
Note: This setting only affects the first alert, all other EPFS alerts are not affected.
1. Rotate the CHANNEL/ENTER knob to select [SYSTEM] on the [MENU] screen
then push the knob.
2. Rotate the CHANNEL/ENTER knob to select [POSITION SETUP] then push the
knob.
3. Rotate the CHANNEL/ENTER knob to select [FIRST ALARM] then push the
knob.
4. Rotate the CHANNEL/ENTER knob to set [FIRST ALARM] time, then push the
knob. The setting range is 10 seconds to 600 seconds and the default setting is
60 seconds.
5.6.2 Position source priority
When more than one source of position data is available and POSITION SETUP is set
to EPFS, the system automatically changes the position source (sensor) based on the
priority outlined in the table below.
Note: When talker and formatter priorities are contradicting, formatter priority is se-
lected. See the sentence definitions outlined in "DIGITAL INTERFACE".
Talker priority GN>GP>GA>GL>GB>GQ>GI>OTHERS (for formatter GGA,
GLL, RMC)
GN>GP>GL (for formatter GNS)
Formatter priority GNS>GGA>RMC>GLL