3. INITIAL SETTINGS
3-2
DIP switch S2 setting options (reference only)
After setting up the DFF-3D transducer, initial settings must also be done on your
NavNet device (NavNet TZtouch/NavNet TZtouch2/NavNet TZtouch3). See respec-
tive Installation Manual for the procedure.
Switch
No.
Function Setting
1 Automatic IP address assignment OFF: Fixed (static) IP address. Set the IP address
with switch #2.
ON: IP address assigned automatically.
2 IP address no. Effective when #1 segment is OFF. (See the table
below for IP address. Currently, this function has no
use.)
3 Restore default settings (other than
LAN)
See section 5.3.
4 Restore ALL default settings See section 5.3.
5 - 6 Keep these switches in the OFF position.
7 No use.
8 No use.
#2 Host name IP address
OFF ES092021 172.031.092.021
ON ES092022 172.031.092.022