1. OPERATIONAL OVERVIEW
1-7
1.4.6 Echo level display
The echo level display shows the strength of the echoes captured by three sounding
beams. Note that [ECHO LEVEL] in the [MODE] sub menu must be set to [ON] to
show the echo level display.
1.5 How to Set the Measuring Depth
Set the depths at which you wish to measure tide speed and direction as below.
Note: The layer 5 cannot be set when [BTM TIDE TRACK] in the [MENU 4] sub menu
is set to [ON] (see subsection 3.3.2).
1. Press the LYR1, LYR2, LYR3, LYR4, or
LYR5 key as appropriate to show the depth
setting window shown right.
Note: This window disappears when there is
no operation for five seconds.
2. Operate the Setting Knob or the CursorPad to set depth of measurement. The set-
ting range is 2-400 (meters).
*: See subsection 1.4.1.
Setting Knob: Rotate clockwise to raise the range; counterclockwise to lower the
range.
CursorPad: Press or to raise the range; or to lower the range.
Beam 2Beam 1Beam 3
Tide Differential
Tide Vector
Echo Level
Echo Display Range
Text Window*