2. INSTALLATION AND INITIAL SETTINGS
2-15
How to set input specification (J4 to J9)
For connectors J4 to J7, the connections are different depending on the input specifi-
cations as shown below.
Connector J4
*: Set the jumpers J20/J21 to Modbus.
Connector J5
*: Set the jumpers J20/J21 to Modbus.
Pin
#
Signal
name
In/
Out
Description IEC 61162-2 IEC 61162-1 Modbus*
1 TD1-A Out Serial CH1, output IEC
61162-1/2/modbus
TTYCS(LA)-4 TTYCS(LA)-4 TTYCS(LA)-4
2 TD1-B Out Serial CH1, output IEC
61162-1/2/modbus
3 RD1-A In Serial CH1, input IEC
61162-2/modbus
No connection No connection
4 RD1-B In Serial CH1, input IEC
61162-2/modbus
5 ISOGND1 - Isolation, GND (CH1)
6 RD1-H In Serial CH1, input IEC
61162-1
No connection TTYCS(LA)-4
7 RD1-C In Serial CH1, input IEC
61162-1
Pin
#
Signal
name
In/
Out
Description IEC 61162-2 IEC 61162-1 Modbus*
1 TD2-A Out Serial CH2, output IEC
61162-1/2/modbus
TTYCS(LA)-4 TTYCS(LA)-4 TTYCS(LA)-4
2 TD2-B Out Serial CH2, output IEC
61162-1/2/modbus
3 RD2-A In Serial CH2, input IEC
61162-2/modbus
No connection No connection
4 RD2-B In Serial CH2, input IEC
61162-2/modbus
5 ISOGND2 - Isolation, GND (CH2)
6 RD2-H In Serial CH2, input IEC
61162-1
No connection TTYCS(LA)-4
7 RD2-C In Serial CH2, input IEC
61162-1