6
SmartSequencing™ 101
Note: A pair of wires between the Primary OUT terminals of one
sequencer and the Secondary IN terminals of a second sequencer is
all that is required. Which terminals are used at the IN port or the OUT
port does NOT matter; the wiring scheme is polarity independent. Please
remember, even non-technical personnel can achieve professional results
with SmartSequencing™. Two wire runs connecting two or more units
create a SmartSequencing chain.
Furman SmartSequencing™ products can be connected end-to-end
to form a chain. Each Contractor Series unit has two communication
ports (OUT and IN) divided into 4 terminals, responsible for full-duplex
transmissions via two bi-directional current loops. The messages com-
municated are in the form of ASCII character strings made more efficient
by utilizing a High-Level Data Link Control. The first SmartSequencer in a
chain is termed the “Primary” or “Primary Unit”; it controls the “other se-
quencers” in the chain. The “other sequencers” are termed “Secondary”
or “Secondary Units”. The Primary Unit only has one active current loop,
because the Primary Unit only has one Secondary sequencer attached
to it. Once again, when sequencers are attached with SmartSequencing,
the first sequencer in the chain is termed the Primary Unit and all the
subsequent sequencers in the chain are termed Secondary Units. And
so the chain continues as additional Secondary Units are attached, OUT
to IN, OUT to IN, OUT to IN, etc. A pair of wires between the Primary OUT
terminals and the Secondary IN terminals is all that is required to create a
continuous SmartSequencing chain.
A Furman SmartSequencing™ chain transmits a message as follows: A
Primary Unit communicates to the first Secondary Unit downstream, by
sending commands out of its Primary OUT terminals to the Secondary
IN terminals of the first Secondary Unit. If there is a second Secondary
Unit in the chain, the first Secondary Unit communicates to the second
Secondary Unit, using its Primary OUT terminals to the second Secondary
Unit’s Secondary IN terminals. This continues down the sequence chain
until the last Secondary Unit. The last Secondary Unit will receive com-
mands into its Secondary IN terminal port but will not use its Primary OUT
terminal port (because there are no Secondary Units after it). Please see
figure to the left:
SmartSequencing™ commands between units are always accepted
when continuity exists, however SmartSequencing commands that control
the outlets are not always allowed. There are two considerations for de-
ciding whether SmartSequencing control commands are allowed: one, the
state of the other CN-1800S functions (i.e: Key Switch, Start Sequence
Push Button, and Remote terminals e.g. Force Off); and two, whether the
Sequencer is configured as a Primary or a Secondary unit.
The Primary Unit has an active DE-9 RS-232 port that can be used to
communicate with a local RS-232 control system or an Ethernet Blue-
BOLT adaptor. When a SmartSequencer is selected as a Secondary Unit
(DIP Switch position 8 is DOWN or OFF), the unit’s RS-232 port is deacti-
vated. The Key Switch and Force Off function will also defeat the RS-232
port functions regardless of the units Primary or Secondary status.
Additional SmartSequencing™ information is available throughout this
instruction manual. More information on SmartSequencing™ can be
found at our contractor website www.furmancontractor.com. Details such
as firmware updates, Quick Start diagrams, etc., can also be found at the
website.
PRIMARY
SECONDARY
SECONDARY
(LAST)
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
START
SEQUENCE
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
DLY
ADJ
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
Front Panel Overview
Start Sequence Push Button
The Start Sequence button can be used for sequencing power up or
power down. This button is located at the left side of the panel. The
START SEQUENCE pushbutton is there to initiate local operation when
the key switch is set to REMOTE. Please note, setting the key switch to
ON defeats operation of the START SEQUENCE pushbutton, keeping in
mind that both the key switch and the START SEQUENCE button operate
in either Maintained or Momentary mode (DIP Switch position 7). If a
number of units are linked via SmartSequencing, or via Remote Terminal,
and unit drops out of sync, press and hold the START SEQUENCE button
for several seconds; this will initiate a re-sync.
PRIMARY LINK
SECONDARY LINK
ETHERNET
DELAY 1
DELAY 2
DELAY 3
POWER
PROTECTION OK
EXTREME VOLTAGE
UNSWITCHED
START
SEQUENCE
15 AMPS
PUSH TO RESET
ON
OFF
REMOTE
DLY
ADJ
1 2 3 4 5 6 7 8 9
1M
1 2 3 4 5
2M
4M
N.O.
N.C.
12V ON
12V OFF
GND
ON
MOM
MNT
PRI
SEC
EVS AUTO
MANUAL
6 7 8 9
START SEQUENCE
PUSH BUTTON
START SEQUENCE PUSH BUTTON
Triggers sequence in remote mode.
• Activates or deactivates sequence
• Hold button to re-sync multiple sequencer
s