Electrical Hook-Up
Before connecting to the electricity, make sure that:
•the characteristics of the electrical system satisfy what is
shown on the serial number plate applied to the front of the
oven;
•the system has an effective earth connection compliant with
current standards and laws.
The earth connection is required by law. The cable must not, at
anypoint,reachatemperaturegreaterthan50°Cabovethe
ambient temperature.
This oven must be connected to the electricity through a power
supply cable and plug that is compatible with the outlet of the
electrical system that powers this oven.
If a fixed appliance does not have a power cord and plug,
or another device that ensures disconnection from the mains,
with an opening distance of the contacts that allows complete
disconnection under the conditions of excessive voltage
category III, such disconnection devices must be provided in
the power supply mains conforming to the installation rules.
The omnipolar socket or switch must be easy to reach when the
appliance is installed.
Note: The manufacturer declines all liability if the usual accident
prevention standards and the above instructions are not
followed.
TYPE AND MINIMUM DIAMETER OF THE CABLES
SASO
H05RR-F 3x1,5mm² H05RR-F 3x2,5mm²
H05VV-F 3x1,5mm² H05VV-F 3x2,5mm²
H05RN-F 3x1,5mm² H05RN-F 3x2,5mm²
H05V2V2-F 3x1,5mm² H05V2V2-F 3x2,5mm²