Fulgor Milano F4MGK24S1 handleiding
Handleiding
Je bekijkt pagina 6 van 72

EN
2
1 - Special Warnings
IMPORTANT
Please read all instructions before using this appliance.
Proper installation is your responsibility. Have a qualified technician install this cooktop.
IMPORTANT
• Observe all governing codes and ordinances.
• Write down the model and serial numbers before installing the
cook top. Both numbers are on the serial rating plate located
on bottom of cooktop box.
Before Starting Installation
• Check location where cooktop will be installed. The location
should be away from strong drafty areas, such as windows,
doors and strong heating vents or fans.
• Electrical grounding is required. See “Electrical Requirements”
• Assure that electrical installation is adequate and in conformance
with National Electrical Code, ANSI/NFPA 70 - latest
edition**, or Canadian Electrical Code, part 1 C22.1 (latest
edition)*** and all local codes and ordinances.
• Assure that gas connection conforms with local codes and
ordinances. In the absence of local codes, installations must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 - latest edition** The Natural
Gas and Propane Installation Code, CSA 149.1 or CSA B149.2
latest edition***.
Copies of the standards listed may be obtained from:
** National Fire Protection Association One Batterymarch Park
Quincy, Massachusetts 02269
*** CSA International 8501 East Pleasant Valley Rd. Cleveland,
OH 44131-5575
NOTE: This cooktop is manufactured for use with Natural gas or
Propane.
To convert to LP (propane) or NG (natural gas), see
instruction in the gas conversion kit provided in literature
package. Proper gas supply connection must be available.
See gas supply requirements.
WARNING
BEFORE CONNECTING THE APPLIANCE ON THE GAS LINE
SUPPLY, ENSURE THAT ITS GAS SETTING IS APPROPRIATE.
THE TYPE OF GAS ADJUSTED AND SHIPPED FROM THE
FACTORY IS INDICATED ON THE RATING PLATE LOCATED
ON BOTTOM OF THE BURNER BOX.
Vent hood Combinations:
It is recommended that these cooktop be installed in conjunction
with a suitable overhead vent hood.
Due to the high heat capacity of this unit, particular attention should
be paid to the hood and ductwork installation to assure it meets
local building codes.
A hood with suitable capture area and capable of at least 450 cfm is
suggested to effectively evacuate odors, steam and heat. Choosing
to install a hood of lower cfm or configured for recirculating may
compromise the effectiveness of eliminating the aforementioned
factors.
Note: some State / Provincial building codes will require make
up air systems be installed for hoods above a certain cfm
threshold (300 cfm is typical).
It is your responsibility to understand and comply with the
local requirements for gas, electrical and ventilation where
these appliances are being installed.
Bekijk gratis de handleiding van Fulgor Milano F4MGK24S1, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Fulgor Milano |
Model | F4MGK24S1 |
Categorie | Fornuis |
Taal | Nederlands |
Grootte | 9846 MB |