Fulgor Milano F4MGK24S1 handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 72
EN
13
Pressure Testing
The appliance must be isolated from the gas supply piping system
by closing its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 PSIG (3.5 kPa).
This appliance, as well as its individual shut-off valve, must be
disconnected from the gas supply piping system during any pressure
testing of the system at test pressures in excess of 1/2 PSIG (3.5
kPa).
When checking appliance regulator function, make certain pressure
of natural gas supply is between 6 and 14 inches of water column
or, if converted for LP gas, between 11 and 14 inches.
THE PRESSURE TESTING SHOULD BE PERFORMED BY MEANS
OF THE INJECTOR THREAD ZONE
Gas test inlet
Thread Pressure
Pressure Test Method
Remove grate and burner cap
Remove aluminum gas spreader
Temporarily remove the injectors
Connect the pressure Test instrument into injector holder thread
zone (M6x0,75)
Check if the cooktop has the correct pressure
Fix the injector removed for testing and replace the parts in the
right position.