Fujitsu AJG072JATAH handleiding

24 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 24
En-23
10. STATUS DISPLAY
10.1. Normal operation codes
Mode CODE DESCRIPTION
Operation
C L
Cooling
o r
During oil recovery operation
P C
During power saving operation
L n
During low noise operation
10.2. Error codes
Mode Code Description
Communication error
E 1 3. 1 Communication error between outdoor units
E 1 4. 1 Outdoor unit network communication 1 error
E 1 4. 2 Outdoor unit network communication 2 error
E 1 4. 5 The number of indoor unit shortage
Function setting error
E 2 8. 1 Auto address setting error
E 2 8. 4 Signal amplifier auto address error
Indoor unit actuator error
E 5 U. 1 Indoor unit miscellaneous error
Outdoor unit PCB/elec-
trical component/switch
error
E 6 1. 2 Outdoor unit under voltage error
E 6 1. 5
Outdoor unit reverse phase, missing phase wire
error
E 6 3. 1 Outdoor unit inverter error
E 6 8. 2
Outdoor unit rush current limiting resister temp. rise
error (protective operation)
Outdoor unit sensor
error
E 7 1. 1 Outdoor unit discharge thermistor 1 error
E 7 2. 1 Outdoor unit compressor temp. sensor 1 error
E 7 4. 1 Outside air thermistor error
E 7 5. 1 Outdoor unit suction gas thermistor error
E 7 7. 1 Outdoor unit heat sink thermistor error
E 8 2. 2
Outdoorunitsub-coolheatex.gasoutletthermis-
tor error
E 8 3. 1 Outdoor unit liquid pipe thermistor 1 error
E 8 3. 2 Outdoor unit liquid pipe thermistor 2 error
E 8 4. 1
Outdoor unit current sensor 1 error (permanent
stop)
E 8 6. 1 Outdoor unit discharge pressure sensor error
E 8 6. 3 Outdoor unit suction pressure sensor error
E 8 6. 4 Outdoor unit high pressure switch 1 error
Outdoor unit actuator
error
E 9 3. 1 Outdoor unit inverter compressor start up error
E 9 4. 1 Outdoor unit trip detection
E 9 5. 5
Outdoor unit compressor motor loss of synchronization
E 9 7. 1 Outdoor unit fan motor lock error
E 9 7. 5
Outdoor unit fan motor temperature error (protec-
tive action)
E 9 7. 9 Outdoor unit fan motor driver error
E 9 8. 1 Outdoor unit fan motor 2 lock error
E 9 8. 5
Outdoor unit fan motor 2 temperature error (protec-
tive action)
E 9 8. 9 Outdoor unit fan motor 2 driver error.
E 9 A. 1 Outdoorunitcoil1(expansionvalve1)error
E 9 A. 3 Outdoorunitcoil3(expansionvalve3)error
Refrigerant system error
E A 1. 1 Outdoor unit discharge temperature 1 error
E A 3. 1 Outdoor unit compressor 1 temperature error
E A 4. 1 Outdoor unit high pressure error
E A 4. 2 Outdoor unit high pressure protection 1
E A 5. 1 Outdoor unit low pressure error
E A C. 4 Outdoor unit heat sink temperature error
㫋㪑
㪣㪑
㪎㪑
㪡㪑
㪍㪑
㪘㪑
㪜㪑
㪻㪑 㫅㪑
㫉㪑
㪐㪑
㪬㪑
㪪㪑
㪏㪑
㪌㪑㪊㪑
㪈㪑
㪉㪑
㪇㪑
7 segment display:
9378945746-01_IM_En_240313.indd 239378945746-01_IM_En_240313.indd 23 2024/03/14 8:55:162024/03/14 8:55:16

Bekijk gratis de handleiding van Fujitsu AJG072JATAH, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkFujitsu
ModelAJG072JATAH
CategorieAirco
TaalNederlands
Grootte5568 MB