Frilec BERLINUWSP2-46-012 handleiding
Handleiding
Je bekijkt pagina 26 van 47

Attention
1. For both upper and lower zone, the cooling temperature can be set from
5-22
℃
. And temperature of lower zone can only be set equal to or higher than
that of upper zone.
2. Alarm sound: when a system malfunction occurs and alarm sounds, press any
key on the control panel to cancel the alarm sound.
3. Error code:
When the temperature sensor failure of upper zone occur, error code displays:
E1 for open circuit; E2 for short circuit.
When the defrost sensor failure occur, error code displays: E3 for open circuit;
E4 for short circuit.
When the temperature sensor failure of Lower zone occur, error code
displays: E5 for open circuit; E6 for short circuit.
Wine storage
The appliance is equipped with sufficient independent shelves to allow your
collection of wine to mature quietly and peacefully.
o
a
d
i
n
g
capacity: bottles. (standard Bordeaux with 750ml )
64
L
BERLINUWSP2-46-012 Version 5-2025 Page 9
The factory default set temperature is 12˚C and the temperature range to be set
should be based on the wine being stored.