This product r
equires a three-prong ground
ed
outlet. T
he installer must perform a ground
co
ntinuity check on the power outlet box before
beginning the installation to ensure that the outlet
box is properly grounded. If not properly grounded,
or if the outlet box does not meet electrical
requirements noted
(under ELECTRICAL REQUIREMENTS), a qualified
electrician should be employed to correct any
deficiencies.
C
AUTION: For
pe
rsonal safety,
r
emove house fuse or
op
en circuit breaker
before beginning
installation to avoid
severe or fatal shock
injury.
C
A
UTION: For personal safety, the mounting surface
m
ust be capable of supporting the cabinet load, in
addition
to the added weight of this 63–85 pound
(28.5–38.5 kg) product, plus additional oven loads of
up to 50 pounds (22.7 kg) or a total weight of
113–135 pounds (51.3–61.2 kg).
CAUTION: For personal safety, this product cannot be
installed in cabinet arrangements such as an island or
a peninsula. It must be mounted to BOTH a top
cabinet AND a wall.
NOTE: For easier installation and personal safety, it is
recommended that two people install this product.
IMPORTANT – PLEASE READ CAREFULLY. FOR
PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED TO AVOID SEVERE OR
FATAL SHOCK.
T
h
e power cord of this
a
pp
liance is equipped
with a three-prong
(grounding) plug which
mates with a standard
three-prong
(grounding) wall
receptacle to minimize
the possibility of electric
shock hazard from this
appliance.
Y
ou should have the wall receptacle and circuit
checked by a qualified electrician to make sure
the receptacle is properly grounded.
Whe
re a standard two-prong wall receptacle is
encountered, i
t is very important to have it
replaced
with a properly grounded three-prong
wall receptacle, installed by a qualified electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT,
DEFORM OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT USE WITH AN
EXTENSION CORD.
I
M
P
ORTANT SAFETY INSTRUCTIONS
E
nsure
proper
ground exists
before use
Installation Instructions
ELECTRICAL
RE
QUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 15 amps
and 1.6 kilowatts. This product must be connected
to a seperate and dedicated supply circuit of the
proper voltage and frequency. Wire size must
conform to the requirements of the National
Electrical Code or the prevailing local code for this
kilowatt rating. The power supply cord and plug
should be brought to a seperate and dedicated 15- to
20- ampere branch circuit single grounded outlet.
The outlet box should be located in the cabinet
above the microwave oven. The outler box and
supply circuit should be installed by a qualifed
electrician and conform to the National Electrical
Code or the prevailing local code.