A. IMPORTANT SAFETY AND GENERAL INFORMATION
Automatic Room Freeze Protection–automatically keeps the temperature in the room from getting too cold, where water pipes might
freeze. If the unit is configured for the freeze protection feature to be active (which is the default condition), then whenever power is supplied to
the unit, and the unit senses the temperature is below 40°F, the fan motor and electric heater are turned on, and will warm the room to 50°F.If
Freeze protection is not required, change the configuration switch to turn the feature off (see section J.3 Dip switches on unit configuration).
Automatic defrost protection –When the outdoor temperature gets too cold (approx. 28°F) and the unit can no longer effectively
heat with the compressor, the unit will automatically switch to electric heating. The unit will then heat with electric heat until the outside
temperature rises enough (approx.40°F), so the compressor can be used again.
Automatic Quick Warmup (for heat pump models only)-If the room temperature falls to 5°F below the set point temperature, the
reverse cycle heat is shut off and the electric strip heat is turned on for one cycle, until heating is satisfied.
LED Indicator’s and Buttons The touch pad has buttons for POWER, UP, DOWN, COOL, HEAT, CONSTANT FAN, HIGH, LOW and AUTO.
It also has LEDs that correspond to the mode, fan speed and setpoint operation, to indicate the unit’s status. The LEDs above the CONSTANT
FAN, COOL, and HEAT mode buttons indicate what operating mode is active. The LEDs above the LOW, AUTO, and HIGH buttons indicate the fan
speed that is selected. The LED above the power button is the unit On/Off status LED. If the unit is in ON mode, the LED will be blue. If the unit is
OFF, the LED will go out.
Configure Fan to Optimize Selected Application Unit can be optimized to selected application by configuring the fan to run in
continuous mode or cycle on and off with the compressor and electric heater. In cycle mode, fan will continue to run for a while after
compressor or electric heater stops in order blow off any residual heat or cool left on coil.
Unit Configuration There are many different configuration possibilities, through both dip switches and the digital keypad, that allow
you to configure the unit for your exact application. See section J.3 on unit configuration for more details. Following are the configuration
selections that have not previously been mentioned:
Temperature Display The unit can display in either °For °C
Indoor Temperature Sensor Biasing Optimize the room temperature sensor reading to your exact application (one for cooling and an
other for heating).
Emergency Heat (for Heat Pump Only) Disable the compressor during heating mode operation (heat only with Electric Heat).
Display Setpoint or Room Temperature The unit can be configured to display the room temperature or setpoint only, during heating
and cooling modes. See section J.3 on unit configuration for more details.
Limit the Setpoint Range The unit can be configured to limit the controlling setpoint range. The display will always show the complete
setpoint range, but the controlling setpoint will be limited to the configured minimum and maximum setpoint selected. See section J.3 on unit
configuration for more details.
Energy Management (Sometimes known as Front Desk Control) an input is provided so that the unit can be manually disabled from a
different location. If the unit detects 24vac on this input, it will automatically turn itself off. If no voltage is detected on the input, the unit will run
normally.
Wall Thermostat Control A wired wall thermostat can be connected to the unit. If it is, the unit must be configured to disable the
keypad. See section J.3 on wired inputs and unit configuration for more details.