TROUBLESHOOTING
Diagnostic Codes
DIAG
CODE
PROBLEM DESCRIPTION CORRECTIVE ACTION
12
Discharge Air greater than
185°F.
Unit Shuts down electric heater. When
discharge air temperature is less than 100°F.
operation resumes.
13
High Pressure Switch Open. Unit shuts down compressor. Operation
resumes after lockout time and pressure
switch closes.
1. With unit power off, disconnect terminal pins of HPS1 and
ohm check to see if circuit is open.
2. If open replace HP switch.
3. If closed check for restriction in refrigeration system
causing high pressure.
14
Discharge Air Temperature
Sensor is Open or Shorted.
Unit overrides sensor and sets temp to 75°F.
Check for open or shorted temp sensor. Refer to Appendix for
temp. sensor values.
15
Inverter communication lost. No communication with inverter board 1. Check wiring from UI to inverter board.
2. Replace UI and cable.
3. Replace Inverter board.
16
Temperature Beyond Operating
Limits.
Ambient temp is less than 0°F or greater than
130°F. Unit turns off compressor, electric
heat, and fan. Operation resumes after fault is
cleared.
Do not operate unit outside of maximum conditions.
22
Outdoor Coil Temperature less
than 30°F for 2 consecutive
Minutes .
Only applicable to units with heat pump
and electric heat. Unit turns off heat pump
operation. Uses electric heat to satisfy all
heating demands. Cleared when outdoor coil
temp is greater than 45°F.
23
Frost Protection. Only applicable to heat pump only units. Active
when Heat Pump run time exceeds 60 minutes
with the outdoor coil temp less than 26°F.
Runs active defrost for up to 6 minutes.
Figure 603