Handleiding
Je bekijkt pagina 12 van 90

13 13
Sleeve
Height
Inches
Width
Inches
Depth
with Front
Inches
Shell
Depth
to Louvers
Inches
Minimum
Extension
Into Room*
Inches
Minimum
Extension
Outside
* Inches
Window Width
INCHES
In-wall Installation
Finished Hole Inches
Carton Dimensions
Inches
Minimum** Maximum Height Width
Max. Depth
Height Width Depth
S
15
15
/16"
25
15
/16" 29"
8
3
/4"
5
3
/4"
16
15
/16"
27
3
/8" 42"
16
3
/16" 26
3
/16"
7
3
/8" 19" 29" 34
1
/2"
M
17
15
/16"
25
15
/16" 29"
8
3
/4"
5
3
/4" 16
15
/16"
27
3
/8" 42"
18
3
/16"
26
3
/16"
7
3
/8" 21" 29"
34
1
/2"
L
20
3
/
16
" 28" 35
1
/
2
" 16
1
/
2
" 5
3
/
8
" 18
15
/
16
" 29
7
/
8
" 42" 20
3
/
8
" 28
1
/
4
" 15
1
/
8
" 24
1
/
2
" 31
5
/
8
" 38
7
/
8
"
Q
14
1
/4"
19
3
/4" 21
3
/8"
8
1
/2"
5
1
/2"
10
3
/4" 22" 42"
14
1
/2" 20"
8
1
/2"
18
3
/4" 22"
25
1
/2"
SPECIFICATIONS
Dimensions
FRONT
SIDE VIEW
SLEEVE DIMENSIONS DRAWING
Installation Clearances
Improper installation of the Air Conditioner can cause poor performance and premature wear of the unit.
Ensure that the KUHL unit is installed with proper clearances as described below.
Ensure no obstructions or enclosures are within clearances limits to allow for proper airow.
Ensure no open ames, or surfaces that will exceed 1000 degrees Fahrenheit are within clearances limits.
Clearances
Top and Bottom of Unit - One (1) foot
Sides of Unit - One (1) foot
Front of Unit - Three (3) feet
Rear of Unit - Three (3) feet
Figure 202 (Kuhl Dimensions)
Figure 203 (Kuhl Sleeve Dimensions)
Height W idth Depth
Height
of Front
Width of
Front
Depth
with
Front
Minimum
Extension Into
Room with
Front
15 ¾" 26 ½" 21" 17 ¼" 27 ½" 23 ¼" 7 ½"
Height W i d t h Depth
Depth
with
Front
Minimum
Extension
Outside
Thru-the-wall
Finished Hole
Height Width Max. Depth
16 ¾" 27" 16 ¾" 24 ¼"
9
/
16
" 17 ¼" 27 ¼" 15
5
/
16
"
Figure 204 (Wallmaster Chassis Dimensions)
Figure 205 (Wallmaster WSE Sleeve Dimensions)
Sleeve Dimensions
Freiedrich
WSE Sleeve
Fedders A
Sleeve
Fedders B
Sleeve*
Height 16
3/4”
16
3/4
” 16
3/4
”
Width 27” 27” 27”
Depth 16
3/4”
16
3/4
” 19
3/4
”
*Installation in a Fedders B sleeve requires a bafe adapter
kit-BAK
Figure 206 (Wallmaster WSE Sleeve Dimensions)
Bekijk gratis de handleiding van Friedrich WallMaster WCVT10B10A, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Friedrich |
Model | WallMaster WCVT10B10A |
Categorie | Airco |
Taal | Nederlands |
Grootte | 17785 MB |