INSTRUCTIONS FOR THE INSTALLER
• INSTALLATION ROOM
This appliance is not provided with a device for exhausting the products of combustion.
Regarding room ventilation rules where appliance is installed make reference to the legislation, in conformity with
the local regulations.
• FOR THE U.K. ONLY
The room containing this hotplate should have an air supply in accordance with BS 5440: Part 2: 1989.
• All rooms require an openable window, or equivalent and some rooms will require a permanent vent a
well.
• For room volumes up to 5m
3
an air vent of 100cm
2
is required.
• For room volumes between 5m
3
and 10m
3
an air vent of 50cm
2
is required.
• If the room is greater than 5m
3
and has a door that opens directly to the outside, then no air vent is required.
If there are other fuel burning appliances in the same room BS 5440: Part 2:1989 should be consulted to determine
the air vent requirements.
• GAS CONNECTION
Make sure that the appliance is adjusted for the gas type available (see the label under the appliance). Follow the
instructions indicated in the chapter “gas transformations and adjustments” for the possible adaptation to di erent
gases.
The appliance must be connected to the gas system by means of sti metal pipes or exible steel pipes having
continuous walls, in compliance with the regulations in force.
Some models are equipped with both cylindrical A and conical B connectors for gas supply ( g. 7). Please select the
type which is correct for the supply concerned.
The connection must not stress the gas ramp.
Once the installation is over, check the connection seal with a soapy solution.
• ELECTRIC CONNECTION
The connection to the electric grid must be carried out by quali ed personnel and in conformity with the regulations
in force.
The voltage of the electric system must correspond to the value indicated in the label under the appliance. Make
sure that the electric system is provided with an e ective ground connction in compliance with the regulations and
provisions of the law. Grounding is compulsory.
GAS TRANSFORMATIONS AND ADJUSTMENTS
• REPLACING THE NOZZLES
If the equipment is adjusted for a type of gas that is di erent from the one available, it is necessary to replace the
burner nozzles.
The choice of the nozzles to replace must be made according to the table of the “technical characteristics” as enclosed.
Act as follows:
• Remove the racks and burners.
• By means of a straight spanner L, unscrew the nozzle U ( g.8) and substitute it with the corresponding one.
• Tighten the nozzle strongly.