4. CONTROLS
Key Key
pressing
Function LED
L
Short Turns the lights on/off at the maximum intensity. -
Long with all
loads off (motor
and lights)
Activates/Deactivates the Activated Carbon Filters alarm.
All the LEDs flash twice:
alarm activated.
All LEDs on for 1
second:
alarm deactivated.
T1
Short Turns the motor on/off at the first speed. Fixed
Long with light
on
24h function
Activates/deactivates the motor in 24h Air Exchange mode, a speed
that allows suction of 10 minutes every hour, for a 24-hour cycle.
It cannot be activated if the Intensive or Delay mode is active.
-
T2
Short It turns on the motor at the second speed. Fixed
Long
Delay Function
It activates/deactivates the Delay function (automatic shutdown of the
Motor and function of lighting delayed by 30').
Cannot be activated with Intensive or 24h on.
Flashing
T3
Short Turns the motor on at the third speed. Fixed
Long with all
loads off (motor
and lights)
The Filter saturation alarm is reset.
All the LEDs flash three
times.
T4
Long with light or
motor on
Turns the motor on at the Intensive speed.
This speed is timed for 6 minutes. At the end of the time, the system
automatically returns to the previously selected speed. If activated
with the motor off, once the time has elapsed, it switches to OFF
mode.
Flashing
Long (both with
door open and
closed)
Activates/Deactivates the remote control. The LED flashes twice:
remote control activ-
ated.
The LED flashes once:
remote control deactiv-
ated.
S1
-
Signals the Metal Grease Filters saturation alarm and the need to
wash them. The alarm goes into operation after 100 hours of actual
hood work.
Fixed
-
Signals the Activated Charcoal Odour Filter saturation alarm. The
alarm goes into operation after 200 hours of actual hood work.
Flashing
5. REMOTE CONTROL
• This appliance can be controlled us-
ing a remote control.
6. LIGHTING
• Please contact the Service Depart-
ment to change it ("Please contact
the service department to purchase
it").
• Lamps in risk group 1 under IEC/
EN62471 at a distance of 20cm and
in exempt from risk group under IEC/
EN62471 at a distance of 30cm.
10
Bekijk gratis de handleiding van Franke FCBI 926 XS, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Franke |
| Model | FCBI 926 XS |
| Categorie | Afzuigkap |
| Taal | Nederlands |
| Grootte | 5313 MB |
Caratteristiche Prodotto
| Kleur van het product | Roestvrijstaal |
| Timer | Ja |
| Breedte | 898.6 mm |
| Diepte | 498.6 mm |
| Netbelasting | 270 W |