Operation
10.5 Homing with end position determination
WARNING
Risk of injury due to unexpected movement of components.
When starting the homing run, the drive is disconnected from the power supply for a short time. This
can cause unexpected movements of the connected mechanics and crush parts of the body.
• Bring moving parts of the connected mechanical system into a safe position.
• Referencing with end position determination is only required again if the reference end posi-
tion"Ref" or the useful range needs to be changed.
• During referencing with end position determination the intermediate position Pos
Imp
and the start
press position Pos
Start Press
is set equal to the new end position Lim
Out
.
During referencing with end position determination the positions of the mechanical stops Mech
In
/
Mech
Out
are recorded in order to calculate the end positions Lim
In
("Ref")/Lim
Out
for the dimension
reference system.
Before running homing with end position determination to a new reference end position "Ref", the
drive is de-energised for a required re-initialisation. Then the power is restored and the process is
started.