Festo EPCS-BS-32-200-3P-A-ST-M-H1-PLK-AA handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 20 van 28
20
Festo — EPCS-BS — 2023-11e
Operation
For simple point-to-point operation the drive can be traversed to the "end positions"Lim
In
/Lim
Out
and
intermediate position Pos
Imp
" target positions (IO-Link only).
Point-to-point operation
Parameterising point-to-point operation
HMI:
Speed Out, Speed In, Force and Start Press
è
10.4 HMI display and control elements
IO-Link (acyclic device data):
Speed Out speed: 0x0101.0, Speed Out
1)
Speed In speed: 0x0100.0, Speed In
1)
Force/torque: 0x0102.0, force
1)2)
Start Press Position Pos
Start Press
: 0x0105.0, Position Start Press [mm]
2)3)4)
End position Lim
Out
: 0x0106.0, end position Out [mm]
4)
Intermediate position Pos
Imp
: 0x0108.0, Intermediate Position [mm]
3)4)
Controlling point-to-point operation via digital inputs
Positioning task Control signals
Mov
In
DI1 [Logic, Pin 5]
Mov
Out
DI2 [Logic, Pin 6]
Start
In
/Mov
In
1 0
Start
Out
/Mov
Out
0 1
Stop
5)
0 0
Switch off power stage
6)
1 1
Control point-to-point operation via IO-Link
Positioning task Process parameters System parameters
Move "In" Move
"Out"
Move
"Inter-
mediate"
System commands
0x0029.1 0x0029.2 0x0029.5 0x0002
Start
In
/Mov
In
true false false =0xC8, execute "Move
In
"
Start
Out
/Mov
Out
false true false = = 0xC9, execute "Move
Out
"
Start
Imp
/Mov
Imp
false false true =0xD0, execute "Move
Intermediate
"
Stop
5)
false false false =0xCA, stop motion
Switch off power stage
6)
³2xtrue =0xCB, disable power stage

Bekijk gratis de handleiding van Festo EPCS-BS-32-200-3P-A-ST-M-H1-PLK-AA, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkFesto
ModelEPCS-BS-32-200-3P-A-ST-M-H1-PLK-AA
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2484 MB