21
PULSE16 I/OsBNC WORDCLOCK
Every digital system needs a clock frequency to work. This clock frequency
can either be generated by the system itself (master/leader mode) or it can
be supplied externally (slave/follower mode). There can be only one
master clock in a digital system. The number of slave/follower devices is
not limited.
The PULSE16 can generate its own clock and share this clock with other
external devices via the BNC OUT connector or it can receive an external
clock from the BNC IN connector. Please use a coaxial cable with an
impedance of 75 ohms.
Whether the PULSE16 runs in Master/leader or Slave/follower mode can
be set inside the CLOCK settings menu.
For creating a rock-solid clock signal, the PULSE16 uses
a proprietary circuit for jitter reduction. All data
coming from MADI, ADAT and BNC is processed by this
jitter reduction stage. This guarantees the lowest jitter
on all digital channels.