GENERAL ELECTRICAL & GROUNDING
DANGER: Improper or faulty hookup of electrical components in the
display case can result in severe injury or death.
MODEL PERMANENT CONNECTED AMPS CORD CONNECT AMPS/NEMA PLUG COMPRESSOR LRA
ITR3626 & ITR3634 MIN CIRCUIT AMPACITY 13.9/ MAX FUSE SIZE 20 TOTAL AMPS 8.7 / 5-15 TOTAL AMPS 8.7 / 5-15
ITR4826 & ITR4834 MIN CIRCUIT AMPACITY 16.9/ MAX FUSE SIZE 20 TOTAL AMPS 10.7 / 5-15 TOTAL AMPS 10.7 / 5-15
ITR6026 & ITR6034 MIN CIRCUIT AMPACITY 17.3/ MAX FUSE SIZE 20 TOTAL AMPS 11.0 / 5-15 TOTAL AMPS 11.0 / 5-15
ITRSS3626 & ITRSS3634 MIN CIRCUIT AMPACITY 17.11/ MAX FUSE SIZE 20 TOTAL AMPS 13.6 / 5-20 TOTAL AMPS 13.6 / 5-20
ITRSS4826 & ITRSS4834 MIN CIRCUIT AMPACITY 20/ MAX FUSE SIZE 25 TOTAL AMPS 13.8 / 5-20 TOTAL AMPS 13.8 / 5-20
ITRSS6026 & ITRSS6034 MIN CIRCUIT AMPACITY 13.65/ MAX FUSE SIZE 20 TOTAL AMPS 10.1 / 6-15 TOTAL AMPS 10.1 / 6-15
MODEL VOLTAGE PERMANENT CONNECTED AMPS
ITR3626 & ITR3634
ITRSS3626 & ITRSS3634
120V/60H/1PH MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
ITR4826 & ITR4834
ITRSS4826 & ITRSS4834
120V/60H/1PH MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
ITR6026 & ITR6034
ITRSS6026 & ITRSS6034
120V/60H/1PH MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15
MODEL PERMANENT CONNECTED AMPS CORD CONNECT AMPS/NEMA PLUG
ITD3626 & ITD3634
ITDSS3626 &ITDSS3634
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15 TOTAL AMPS 2.0 / 5-15
ITD4826 & ITD4834 ITDSS
4826 & ITDSS4834
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15 TOTAL AMPS 2.0 / 5-15
ITD6026 & ITD6034
ITDSS6026 & ITDSS 6034
MIN CIRCUIT AMPACITY 15/ MAX FUSE SIZE 15 TOTAL AMPS 2.0 / 5-15
SELF CONTAINED
VOLTAGE
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
230/60H/1PH
DRY NON REFRIGERATED
VOLTAGE
120V/60H/1PH
120V/60H/1PH
120V/60H/1PH
REMOTE
(E3788 EXCEL)
Refrigerated Permanent Connected
-Only a licensed electrician must perform all case electrical connections.
-All electrical wiring hookups must be done in accordance with all applicable local, regional, or national
electrical standards.
-A separate circuit for each display case is required to prevent other appliances on the same circuit from
overloading the circuit and causing malfunction.
-The electrical service must be grounded upon installation.
-See the electrical data plate located at the rear of the case for proper circuit size and wire ampacity.
-The electrical connection box is accessible from the rear of the case with rear grill removed. See grill
removal section of this manual for grill removal procedure.