PERIODIC MAINTENANCE
NOTICE: Condenser coil must be cleaned a minimum of twice per month to insure
proper refrigeration performance and prevent compressor failure.
Failure to clean condenser coil will void condenser warranty.
Cleaning Condenser Coil (All Self Contained Refrigerated Units)
It is very important that the Condenser coil is cleaned twice per month to insure proper refrigeration
performance and to prevent compressor failure. Failure to clean condenser coil will void condenser
warranty.
1. Disconnect power to the unit.
2. Remove the back base panel located on the back bottom of unit by removing the (6) front panel
retaining screws.
3. Carefully vacuum the front surface of condenser coil. Take care not to bend coil fins with vacuum
cleaner nozzle.
4. Reinstall back panel and retaining screws.
VACUUM FRONT
SURFACE OF
CONDENSER COIL
(6) REAR BASE
PANEL SCREWS