Intellicomfort CH121E
Index Parameter Default Values
P01 display mode 1 1 = view room temp
2 = view set point
P02 correction of displayed tem-
perature value
0.0°C +/- 4°C (step 0.1°C)
P03 winter lower limit set point
temperature
2.0°C 2.0°C……40.0°C (step 1.0°C)
P04 winter upper limit set point
temperature
40.0°C 2.0°C……40.0°C (step 1.0°C)
P05 summer lower limit set point
temperature
2.0°C 2.0°C……40.0°C (step 1.0°C)
P06 summer upper limit set point
temperature
40.0°C 2.0°C……40.0°C (step 1.0°C)
P07 differential adjustment 0.3°C ±0.3°C…….±2.0°C *
(step 0.1°C)
P08 temperature scale CEL CEL = Celsius
FAH = Fahrenheit
END exit parameter configuration
and store values
* ± 0.3°C value suited for plants with slow thermal inertia,
± 2°C value suited for very reactivate plants.